How to keep your broadband working in a power cut
Power the Wi-Fi router and, if you have full fibre, the separate connection box. A small battery can keep both running while your provider’s network stays up. At 18 W together, they use 144 Wh in eight hours before the battery’s own losses.
Which boxes need power?
Follow the cable that brings broadband into your home. On an Openreach full-fibre connection, the optical network terminal (ONT) is the small powered box where the fibre enters. An Ethernet cable connects it to your router. Back up both mains adaptors. For a combined modem and router you may only have one mains plug. If you rely on a separate powered Wi-Fi access point or mesh unit for coverage where you work, include that too. Openreach’s equipment guide
If you rely on a digital landline for emergency calls, contact your provider first. Ofcom says providers should offer a free backup solution to customers who depend on their landline to call the emergency services during a power cut. A cordless phone’s base may need its own power. Ofcom’s rules for providers · Digital landline guidance
Will my digital landline work in a power cut?
A digital landline needs power for the relevant broadband equipment. Include the fibre connection box where fitted, the router, and a cordless handset’s powered base if used. A corded handset plugged into the router still relies on that router’s power. Keeping Wi-Fi available is not proof that calls, including emergency calls, work.
Ofcom says providers must offer a solution allowing access to emergency organisations for at least one hour in a power cut, free to people who depend on their landline for emergency calls. Ask your provider about eligibility and its approved solution before paying for a generic battery. Some arrangements use a mobile connection rather than backing up all the broadband equipment.
If you use a telecare alarm, contact the alarm provider and phone provider about compatibility and power-cut operation. The government’s telecare action plan explains the coordination needed. A portable station alone does not certify that an alarm can reach its monitoring centre.
Should I buy a larger battery for the phone?
Only after checking the provider’s option and the equipment that it covers. For an additional eight hours at an illustrative 18 W, the equipment itself needs 144 Wh before battery overhead. Use the runtime table below for planning, then test the actual arrangement with the provider’s guidance.
Mini UPS, mains UPS or power station?
Mini DC UPS for broadband alone
Start with your provider’s compatible option if it has one. A mini DC UPS replaces one or more mains adaptors and avoids running a mains inverter. Check each device’s voltage, required current, connector size and polarity against the backup unit. If your router and fibre box use different adaptors, verify both outputs before ordering. When the match is unclear, keep the original adaptors and use a mains-backed option.
Mains UPS for a short interruption
The UK APC Back-UPS BE650G2-UK is a straightforward option when you want the original adaptors to stay plugged in through a short cut. Use the battery-backed outlets and check the manufacturer’s runtime curve for your load. Its 400 W output rating tells you how much it can power at once. It takes a separate runtime figure to tell you how long. APC UK specifications
As an Amazon Associate I earn from qualifying purchases.
APC Back-UPS BE650G2-UK on Amazon UK (paid link)
Portable station for several hours or more equipment
The 288 Wh BLUETTI Elite 30 V2 has one UK mains socket. Consider it if you only have one plug to power. With a separate router and fibre box, look at the EcoFlow RIVER 3 Plus or the Anker C300X with mains sockets. Both can take the original adaptors. Check how they fit and how the station behaves with a light load. BLUETTI UK specifications · EcoFlow UK specifications · Anker UK specifications
BLUETTI Elite 30 V2 on Amazon UK (paid link)
EcoFlow RIVER 3 Plus on Amazon UK (paid link)
Compare the two compact stations · Compare a UPS and a power station for a desktop or NAS
What a household router actually used
National Energy Action measured a Vodafone THG3000g with a plug-in meter over three days. It averaged 9 W, or 216 Wh a day, although its adaptor was rated at 30 W. This is one router, not a full-fibre router-and-connection-box measurement. It illustrates why the adaptor’s maximum is a poor runtime estimate. NEA appliance monitoring report, router section (PDF)
How long will broadband run on a battery?
Use a suitable plug-in electricity meter to measure the equipment as you normally use it. Add both adaptors if there are two. Multiply the combined draw by the hours you want covered. The table uses the linked 2025 Elite 30 V2 manual’s calculation for a steady mains load, with a 288 Wh battery, 95% depth of discharge, 90% inverter efficiency and 9 W station draw. These are estimates using that manual, not measurements from your home. BLUETTI now also markets a Green version with a different standby claim. Do not transfer this calculation to another version without checking its manual. BLUETTI manual and calculation (PDF)
| Equipment draw | Energy needed for 8 hours | Estimated runtime |
|---|---|---|
| 12 W | 96 Wh | About 12 hours |
| 18 W | 144 Wh | About 9 hours |
| 25 W | 200 Wh | About 7 hours |
Test before relying on it
Check whether the battery keeps its sockets on with a small load. BLUETTI’s manual says AC-ECO can turn its socket off at low loads. Follow the station’s manual to test a changeover while your equipment is running, then check that you can still reach the internet. Keep a charged phone ready for tethering if you have usable mobile reception and your fixed line goes down.
If you need to work from home
Start with your laptop’s own battery. If you need its charger all day and it averages 35 W, adding the 18 W broadband setup gives 53 W. Eight hours uses 424 Wh before station losses. Meter your own laptop during your normal work, including video calls and charging. If the full eight hours matters, see our 1 kWh comparison. See the quick buying picks for broadband.
Plan a full day with a laptop, monitor and broadband.
If the fixed network fails, a powered router cannot restore it. Where mobile coverage remains available, the 4G and 5G broadband guide covers the battery budget and the limits of a mobile fallback.