Battery backup for an aquarium in a power cut
Start by identifying which equipment keeps your particular tank stable. Filtration and aeration often need little power. A heater can dominate the battery budget as the room cools. Size from the equipment and temperature conditions, rather than tank volume alone.
Make an emergency plan for the tank first
UK Power Networks suggests a battery-powered air pump with a bubble-up filter as a basic outage option. The time available depends on the tank and its livestock. Ask your aquatic specialist which equipment has priority and what to do after filtration has stopped. UK Power Networks aquarium advice · NT Labs power-cut guidance
A portable station lets you keep compatible existing mains equipment running. List the filter, air pump, heater, controller and any other essential device separately. Include light only where your livestock’s care plan requires it during the interruption. Keep the station dry, positioned clear of splashes, and follow the aquarium equipment’s cable and electrical protection instructions.
Why the heater changes the answer
Here is a sizing example with a 10 W filter and a 100 W heater. These are illustrative equipment ratings. If the heater runs for a quarter of the time, it averages 25 W and the total is 35 W. If it stays on continuously, the total is 110 W. Measure the whole aquarium over a representative day if you can, and allow for a colder room during the outage.
| Example load | 1,024 Wh | 2,048 Wh |
|---|---|---|
| 10 W filter only | 35 hours | 70 hours |
| Filter + heater at 25% duty | 17 hours | 35 hours |
| Filter + heater continuously | 7 hours | 14 hours |
The first row is an electrical calculation, not a recommendation to switch off heating for that length of time. Your tank’s requirements decide which row is relevant. The assumed 15 W station overhead also shows why a dedicated battery air pump can stretch modest storage much further for aeration alone.
Which battery size would we consider?
For a measured moderate load and overnight backup, the Anker C1000 Gen 2 is a 1 kWh candidate with four UK sockets. If your heater budget needs closer to a full day, compare the C2000 Gen 2 with the other 2 kWh options. Verify low-load behaviour and restart before depending on either.
As an Amazon Associate I earn from qualifying purchases.
Anker SOLIX C1000 Gen 2 on Amazon UK (paid link)
Anker SOLIX C2000 Gen 2 on Amazon UK (paid link)
Test the complete setup
Follow the station and equipment manuals for a supervised changeover test. Check that the filter restarts and the heater controller retains its setting. Check that a low-load timer cannot switch off the sockets while the heater is between cycles. If you need automatic backup while away, test the supported bypass or UPS mode with the intended load and keep a way to notice a failure.
For cuts that last beyond one charge, plan a recharge source. A portable solar panel may help in daylight, but keep enough stored energy for the darkest period you need to cover.